GGT (Gamma GT) Assay Kit

0 out of 5

$120.00

Summary:
Gamma-glutamyltransferase (GGT) is used in the diagnosis and monitoring of he-patobiliary diseases. The enzymatic activity of GGT is often the only parameter with increased values when testing for such diseases, and is one of the most sen-sitive indicators. Gamma-glutamyltransferase is also a sensitive screening test for occult alcoholism. Elevated GGT activities are found in the serum of patients requiring long-term medication with phenobarbital and phenytoin. In 1969, Szasz published the first kinetic procedure for GGT in serum using y- glutamyl-p-nitro-anilide as substrate and glycylglycine as acceptor. In order to circumvent the poor solubility of Y-glutamyl-p-nitroanilide, Persijn and van der Silk investigated vari-ous derivatives of the compound with respect to solubility. The substrate L-Y-glutamyl-3-carboxy-4-nitroanilide is superior in terms of stability and solubility. The assay described beiow uses the water-soluble substrate L-Y-glutamyl-3- car-boxy-4-nitroanilide. The results correiate with those derived using the original substrate.

Category: Colorimetric Kits

Description

 

CATALOG # OttoBC141
PRODUCT NAME GGT (Gamma GT) Assay Kit
APPLICATIONS Fully automated analyzer, Spectrophotometer
REACTIVITY Universal
SAMPLES TYPE Serum, Plasma (Edta or Heparin)
Content Explanation Shelf life
Reagent-1 1x30ml 6 months
Reagent-2 1x8ml 6 months
Calibrator 1×0.5ml 6 months
Q.Control 1×0.5ml 6 months

1. Glick M.R.. Ryder K.W.. Jackson SA. Graphical Comparisons of Interferences in Clinical Chemistry Instrumentation, Clin Chem 1986;32:470-474
2. Persijn JP, van der Silk W. A mew method for the determination of gammag-lutamyltransferase J Clin Chem Biochem 1976;4:421
3. Shaw L M .Keeping pace with a popular enzyme GGT. Diagnostic Medicine 1982; may/June1-8
4. Szasz G.. A kinetic photometric method for serum g-glutamyl-transferase J. Clin Chem 1969;15:124-136
5. Szasz G.. Methods of Enzymatic Analysis 2nd English ed New York: Academic Press Inc. 1974:717
6. Szasz G.. Persijn J.P. et al. Z Klin Chem Klin Biochem 1974;12:228
7. Thomas L. Clinical Laboratory Diagnostics. 4th ed. Marburg: Die Medizinsche Verlagsgesellschaft; 1992
8. Tietz NW. Clinical Guide to Laboratory Tests 3rd ed. Philadelphia, Pa. W.B.Saunders Company. 1995:286
9. Zawta B. Klein G. Bablock W. Temperature Conversion in Clinical Enzymology Klin Lab 1994;40:33-42
10. Thomas L, Klein G. Neue vorläufige Normalbereiche für neun Serumenzyme. Deutsches Ärzteblatt 2006;103;Heft 7.